Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Comput Biol Med ; 172: 108262, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38479196

RESUMO

Given the increasing aging population and rising living standards in China, developing an accurate and straightforward thermoregulation model for the elderly has become increasingly essential. To address this need, an existing one-segment four-node thermoregulation model for the young was selected as the base model. This study developed the base model considering age-related physical and physiological changes to predict mean skin temperatures of the elderly. Measured data for model optimization were collected from 24 representative healthy Chinese elderly individuals (average age: 67 years). The subjects underwent temperature step changes between neutral and warm conditions with a temperature range of 25-34 °C. The model's demographic representation was first validated by comparing the subjects' physical characteristics with Chinese census data. Secondly, sensitivity analysis was performed to investigate the influences of passive system parameters on skin and core temperatures, and adjustments were implemented using measurement or literature data specific to the Chinese elderly. Thirdly, the active system was modified by resetting the body temperature set points. The active parameters to control thermoregulation activities were further optimized using the TPE (Tree-structured Parzen Estimator) hyperparameter tuning method. The model's accuracy was further verified using independent experimental data for a temperature range of 18-34 °C for Chinese elderly. By comprehensively considering age-induced thermal response changes, the proposed model has potential applications in designing and optimizing thermal management systems in buildings, as well as informing energy-efficient strategies tailored to the specific needs of the Chinese elderly population.


Assuntos
Temperatura Alta , Modelos Biológicos , Humanos , Idoso , Regulação da Temperatura Corporal/fisiologia , Temperatura Corporal/fisiologia , Temperatura Cutânea , China
2.
Innovation (Camb) ; 5(2): 100588, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38440259

RESUMO

The combination of urbanization and global warming leads to urban overheating and compounds the frequency and intensity of extreme heat events due to climate change. Yet, the risk of urban overheating can be mitigated by urban green-blue-grey infrastructure (GBGI), such as parks, wetlands, and engineered greening, which have the potential to effectively reduce summer air temperatures. Despite many reviews, the evidence bases on quantified GBGI cooling benefits remains partial and the practical recommendations for implementation are unclear. This systematic literature review synthesizes the evidence base for heat mitigation and related co-benefits, identifies knowledge gaps, and proposes recommendations for their implementation to maximize their benefits. After screening 27,486 papers, 202 were reviewed, based on 51 GBGI types categorized under 10 main divisions. Certain GBGI (green walls, parks, street trees) have been well researched for their urban cooling capabilities. However, several other GBGI have received negligible (zoological garden, golf course, estuary) or minimal (private garden, allotment) attention. The most efficient air cooling was observed in botanical gardens (5.0 ± 3.5°C), wetlands (4.9 ± 3.2°C), green walls (4.1 ± 4.2°C), street trees (3.8 ± 3.1°C), and vegetated balconies (3.8 ± 2.7°C). Under changing climate conditions (2070-2100) with consideration of RCP8.5, there is a shift in climate subtypes, either within the same climate zone (e.g., Dfa to Dfb and Cfb to Cfa) or across other climate zones (e.g., Dfb [continental warm-summer humid] to BSk [dry, cold semi-arid] and Cwa [temperate] to Am [tropical]). These shifts may result in lower efficiency for the current GBGI in the future. Given the importance of multiple services, it is crucial to balance their functionality, cooling performance, and other related co-benefits when planning for the future GBGI. This global GBGI heat mitigation inventory can assist policymakers and urban planners in prioritizing effective interventions to reduce the risk of urban overheating, filling research gaps, and promoting community resilience.

3.
J Hazard Mater ; 465: 133360, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38157815

RESUMO

BACKGROUND: Dibutyl phthalate (DBP), a commonly used plasticizer, has been found to be strongly linked to a consistently high prevalence of allergic diseases, particularly allergic asthma. Previous animal experiments have demonstrated that exposure to DBP can worsen asthma by triggering the production of calcitonin gene-related peptide (CGRP), a neuropeptide in the lung tissue. However, the precise neuroimmune mechanism and pathophysiology of DBP-exacerbated allergic asthma with the assistance of CGRP remain unclear. OBJECTIVE: The present study was to investigate the potential pathophysiological mechanism in DBP-exacerbated asthma from the perspective of neural-immune interactions. METHODS AND RESULTS: C57BL/6 mice were orally exposed to different concentrations (0.4, 4, 40 mg/kg) of DBP for 28 days. They were then sensitized with OVA and nebulized with OVA for 7 consecutive excitations. To investigate whether DBP exacerbates allergic asthma in OVA induced mice, we analyzed airway hyperresponsiveness and lung histopathology. To investigate the activation of JNC and TRPV1 neurons and the release of CGRP by JNC cells, we measured the levels of TRPV1 channels, calcium inward flow, and downstream neuropeptide CGRP. Results showed that TRPV1 expression, inward calcium flux, and CGRP levels were significantly elevated in the lung tissues of the 40DBP + OVA group, suggesting the release of CGRP by JNC cells. To counteract the detrimental effects of DBP mediated by CGRP, we employed olcegepant (also known as BIBN-4096), a CGRP receptor specific antagonist. Results revealed that 40DBP + OVA + olcegepant led to notable decreases in TRPV1, calcium inward flow, and CGRP expression in lung tissues compare with 40DBP + OVA, further supporting the efficacy of olcegepant. Additionally, we also conducted ILC2 flow sorting and observed that neuropeptide CGRP-activated ILC2 cells have a crucial role as key effector cells in DBP-induced neuroimmune positive feedback regulation. Finally, we examined the protein expression of CGRP, GATA3 and P-GATA3, and found that significant upregulations of CGRP and P-GATA3 in the 40DBP + OVA group, suggest that GATA3 acted as a key regulator of CGRP-activated ILC2. CONCLUSION: The aforementioned studies indicate that exposure to DBP can exacerbate allergic asthma, leading to airway inflammation. This exacerbation occurs through the activation of TRPV1 in JNC, resulting in the release of CGRP. The excessive release of CGRP further promotes the release of Th2 cytokines by inducing the activation of ILC2 through GATA phosphorylation. Consequently, this process contributes to the development of airway inflammation and allergic asthma. The increased production of Th2 cytokines also triggers the production of IgE, which interacts with FcεRI on JNC neurons, thereby mediating neuro-immune positive feedback regulation.


Assuntos
Asma , Hipersensibilidade , Neuropeptídeos , Camundongos , Animais , Peptídeo Relacionado com Gene de Calcitonina/toxicidade , Peptídeo Relacionado com Gene de Calcitonina/metabolismo , Imunidade Inata , Retroalimentação , Dibutilftalato/toxicidade , Neuroimunomodulação , Cálcio , Linfócitos , Camundongos Endogâmicos C57BL , Asma/induzido quimicamente , Asma/metabolismo , Pulmão/patologia , Citocinas , Neuropeptídeos/toxicidade , Inflamação/patologia , Camundongos Endogâmicos BALB C , Ovalbumina
4.
Sci Total Environ ; 912: 169613, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38154627

RESUMO

BACKGROUND: The potential role of dermal exposure diisononyl phthalate (DINP) as an adjuvant in allergic inflammation and asthma has been suggested. However, the current findings do not provide enough evidence to support this claim. OBJECTIVES: The purpose of this investigation was to examine the impact and mechanisms of allergic asthma exacerbation through the dermal exposure to DINP. METHODS: The study was undertaken using OVA-sensitized mice. Lung histopathology and airway hyperreactivity (AHR) were assessed. Expression levels of immunoglobulins (t-IgE, OVA-IgE and OVA-IgG1), cytokines (IL-31, IL-4, IL-5, IL-6, IL-13 and INF-γ), and TRPV1 were measured. To investigate the mechanism by which allergic asthma worsens due to dermal exposure to DINP, the blockade analysis using the IL-31 antagonist SB-431542 and the TRPV1 antagonist capsazepine (CZP) were performed. RESULTS: The findings of the study revealed that the simultaneous exposure to DINP and OVA resulted in an increase in inspiratory resistance (Ri) and expiratory resistance (Re), a decrease in the minimum value of lung dynamic compliance (Cldyn), and worsened airway remodeling. Additionally, it was found that this exposure led to an increase in the levels of IL-31 and TRPV1, which are biomarkers of Th2 cytokines (IL-4, IL-5, IL-6, and IL-13), as well as immunoglobulins (Total IgE, OVA-lgE, and OVA-IgG1), while decreasing the biomarker of Th1 cytokines (IFN-γ). However, these impairments showed improvement after the administration of SB-431542 or CZP. CONCLUSION: The findings of this research indicate that the IL-31/TRPV1 pathway plays a moderating function in OVA-induced allergic asthma worsened by dermal exposure to DINP.


Assuntos
Asma , Benzamidas , Dioxóis , Interleucina-13 , Ácidos Ftálicos , Canais de Cátion TRPV , Camundongos , Animais , Ovalbumina/toxicidade , Interleucina-13/toxicidade , Interleucina-4/toxicidade , Interleucina-4/metabolismo , Camundongos Endogâmicos BALB C , Interleucina-5/toxicidade , Interleucina-6 , Asma/metabolismo , Pulmão/patologia , Citocinas/metabolismo , Imunoglobulina E , Imunoglobulina G , Líquido da Lavagem Broncoalveolar
5.
Ecotoxicol Environ Saf ; 255: 114800, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36933481

RESUMO

Epidemiological studies have demonstrated that particulate matter (PM) can induce or exacerbate hypertension. High relative humidity has been associated with elevated blood pressure in certain regions. However, the coupling effect of humidity and PM on elevated blood pressure and the underlying mechanisms remain unknown. Herein, we aimed to explore the effects of exposure to PM and/or high relative humidity on hypertension, as well as elucidate underlying mechanisms. Male C57/BL6 mice were intraperitoneally administered NG-nitro-L-arginine methyl ester (L-NAME) to establish a hypertensive mouse model. The hypertensive mice were exposed to PM (0.15 mg/kg/day) and/or different relative humidities (45/90%) for eight weeks. Histopathological changes, systolic blood pressure (SBP), endothelial-derived contracting factors (thromboxane B2 [TXB2], Prostaglandin F2α [PGF2α], endothelin-1 [ET-1], and angiotensin II [Ang II]), and relaxing factors (prostaglandin I2 [PGI2] and nitric oxide [NO]) were measured to assess the effects of PM exposure and humidity on hypertension in mice. Levels of transient receptor potential vanilloid 4 (TRPV4), cytosolic phospholipase A2 (cPLA2), and cyclooxygenase 2 (COX2) were measured to explore their potential mechanisms. Herein, exposure to 90% relative humidity or PM alone had a slight but insignificant effect on hypertension. However, pathological changes and elevated blood pressure were markedly exacerbated following exposure to PM and 90% relative humidity. Levels of PGF2α, TXB2, and ET-1 were significantly increased, whereas the PGI2 level was substantially decreased. HC-067047-mediated blockade of TRPV4 suppressed TRPV4, cPLA2, and COX2 expression and effectively alleviated the increased blood pressure induced by exposure to PM and 90% relative humidity. These results indicate that 90% relative humidity and PM can activate the TRPV4-cPLA2-COX2 ion channel in the aorta, altering the endothelial-derived contracting and relaxing factors and enhancing blood pressure in hypertensive mice.


Assuntos
Antineoplásicos , Hipertensão , Animais , Masculino , Camundongos , Antineoplásicos/farmacologia , Pressão Sanguínea , Ciclo-Oxigenase 2/genética , Ciclo-Oxigenase 2/metabolismo , Umidade , Hipertensão/induzido quimicamente , Óxido Nítrico/metabolismo , Canais de Cátion TRPV/metabolismo , Canais de Cátion TRPV/farmacologia , Canais de Cátion TRPV/uso terapêutico , Fosfolipases A2 Citosólicas/metabolismo
6.
Sci Total Environ ; 861: 160587, 2023 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-36470381

RESUMO

Many primary schools in the UK are situated in close proximity to heavily-trafficked roads, yet long-term air pollution monitoring around such schools to establish factors affecting the variability of exposure is limited. We co-designed a study to monitor particulate matter in different size fractions (PM1, PM2.5, PM10), gaseous pollutants (NO2, O3 and CO) and meteorological parameters (ambient temperature, relative humidity) over a period of one year. The period included phases of national COVID-19 lockdown and its subsequent easing and removal. Statistical analysis was used to assess the diurnal patterns, pollution hotspots and underlying factors driving changes. A pollution episode was observed early in January 2021, owing to new year celebration fireworks, when the daily average PM2.5 was around three-times the World Health Organisation limit. PM2.5 and NO2 exceeded the threshold limits on 15 and 10 days, respectively, as the lockdown eased and the school reopened, despite the predominant wind direction often being away from the school towards the roads. The peak concentration levels for all pollutants occurred during morning drop-off hours; however, some weekends showed higher or comparable concentrations to those during weekdays. The strong disproportional Pearson correlation between CO and temperature demonstrated the possible contribution of local sources through biomass burning. The impact of lifting restrictions after removing the weather impact showed that the average pollution levels were low in the beginning and increased by up to 22.7 % and 4.2 % for PM2.5 and NO2, respectively, with complete easing of lockdown. The Prophet algorithm was implemented to develop a prediction model using an NO2 dataset that performed moderately (R2, 0.48) for a new monthly dataset. This study was able to build a local air pollution database at a school gate, which enabled an understanding of the air pollution variability across the year and allowed evidence-based mitigation strategies to be devised.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , COVID-19 , Poluentes Ambientais , Humanos , Poluentes Atmosféricos/análise , Dióxido de Nitrogênio/análise , COVID-19/epidemiologia , Controle de Doenças Transmissíveis , Poluição do Ar/análise , Material Particulado/análise , Poluentes Ambientais/análise , Monitoramento Ambiental
7.
Indoor Air ; 32(9): e13113, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36168229

RESUMO

The presence of dampness and visible molds leads to concerns of poor indoor air quality which has been consistently linked with increased exacerbation and development of allergy and respiratory diseases. Due to the limitations of epidemiological surveys, the actual fungal exposure characteristics in residences has not been sufficiently understood. This study aimed to characterize household fungal diversity and its annual temporal and spatial variations. We developed combined cross-sectional survey, repeated air sampling around a year, and DNA sequencing methods. The questionnaire survey was conducted in 2019, and 4943 valid cases were received from parents; a follow-up case-control study (11 cases and 12 controls) was designed, and onsite measurements of indoor environments were repeated in typical summer, transient season, and winter; dust from floor and beddings in children's room were collected and ITS based DNA sequencing of totally 68 samples was conducted. Results from 3361 children without changes to their residences since birth verified the significant associations of indoor dampness/mold indicators and prevalence of children-reported diseases, with increased adjusted odd ratios (aORs) >1 for studied asthma, wheeze, allergic rhinitis, and eczema. The airborne fungal concentrations from air sampling were higher than 1000 CFU/m3 in summer, regardless of indoors and outdoors, indicating an intermediate pollution level. The DNA sequencing for dust showed the Aspergillus was the predominant at genus level and the Aspergillus_penicillioides was the most common at species level; while the fungal community and composition varied significantly in different homes and seasons, according to α and ß diversity analyses. The comprehensive research methods contribute to a holistic understanding of indoor fungal exposure, including the concentrations, seasonal variations, community, and diversity, and verifies the relations with children's adverse health outcomes. The study further elucidates the role of microbiome in human health, which helps setting health-protective thresholds and managing mold treatments in buildings, to promote indoor air quality and human well-beings.


Assuntos
Poluição do Ar em Ambientes Fechados , Rinite Alérgica , Poluição do Ar em Ambientes Fechados/análise , Estudos de Casos e Controles , Criança , Estudos Transversais , Poeira , Fungos , Visita Domiciliar , Humanos , Rinite Alérgica/epidemiologia , Inquéritos e Questionários
8.
Sci Total Environ ; 817: 152695, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-34974019

RESUMO

The changing climate is one of the most important factors affecting public health. Older people are particularly threatened due to their less efficient immune systems. To evaluate the potential benefits of short-term indoor dehumidification on their circulation and cardiopulmonary health, we conducted a random, cross-over experiment with 36 healthy residents of an aged-care center in Chongqing, China in 2020. Vapor compression dehumidifiers were used over two 48-h periods. At the end of each 48 h, we immediately measured sixteen circulatory system biomarkers of inflammation, coagulation, and oxidative stress; lung function; blood pressure; and heart rate. Indoor temperature and relative humidity were monitored throughout the study period. Linear, mixed-effect models were used to associate health endpoints with indoor relative humidity. This intervention study showed that when the indoor relative humidity decreased from 75% to 45%: (1) the coagulation indicators, sCD40l, and PAI-1, decreased significantly, by 58.82% and 23.50%, respectively; (2) the inflammatory indicators, CRP, IL-6, and TNF-α decreased significantly, by 4.09%, 25.78%, and 10.60%, respectively; (3) PEF, FEV1 and FVC were increased significantly by 20.08%, 14.54%, and 15.75% respectively. To the best of our knowledge, this is the first study to examine the impact of short-term dehumidification on clinical and biochemical measures of cardiorespiratory health in humid areas, and our study suggests that RH in the dehumidified rooms (46.9 ± 8.7%) may be healthier than that in humid rooms (75.2 ± 7.9%). Humidity may be involved in the development of atherosclerosis by activating oxidative stress and mediating the secretion of inflammatory indicators. At the same time, platelet activation induced by oxidative stress stimulates thrombosis to increase cardiovascular risk in older people. Conclusion: This intervention study shows that in a Chinese city like Chongqing with serious indoor environmental humidity, indoor short-term dehumidification has obvious cardiopulmonary benefits for the healthy elderly.


Assuntos
Poluição do Ar em Ambientes Fechados , Idoso , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , China , Cidades , Humanos , Umidade , Testes de Função Respiratória , Temperatura
9.
Sci Total Environ ; 798: 149248, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34325134

RESUMO

Exposure to indoor air particulate pollution increases respiratory and cardiovascular morbidity and mortality, especially in the elderly. To assess a short-term, indoor air filtration's potential benefit on circulatory and cardiopulmonary health among healthy older people, a randomized, double-blind crossover trial was conducted with 24 healthy residents of an aged-care center in Chongqing, China in 2020. Each room received a high-efficiency particulate air filter air purifier and a placebo air purifier for two days. Fifteen circulatory system biomarkers of inflammation, coagulation, and oxidative stress; lung function; blood pressure (BP); heart rate (HR) and fractional exhaled nitric oxide (FeNO) were measured end of each two days. Indoor air particulate pollution was monitored throughout the study period. Linear mixed-effect models were used to associate health outcome variables with indoor particles. This intervention study demonstrated that air filtration was associated with significantly decreased concentrations of inflammatory and coagulation biomarkers, but not of biomarkers of oxidative stress and lung function. Just 48 h of air filtration can improve the cardiopulmonary health of the elderly. Air purifiers may be a public health measure that can be taken to improve circulatory and cardiopulmonary health among older people.


Assuntos
Filtros de Ar , Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Idoso , Poluentes Atmosféricos/efeitos adversos , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Estudos Cross-Over , Filtração , Humanos , Material Particulado/efeitos adversos , Material Particulado/análise , Testes de Função Respiratória
10.
Indoor Air ; 29(2): 308-319, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30506551

RESUMO

The extensive research interests in environmental temperature can be linked to human productivity/performance as well as comfort and health; while the mechanisms of physiological indices responding to temperature variations remain incompletely understood. This study adopted a physiological sensory nerve conduction velocity (SCV) as a temperature-sensitive biomarker to explore the thermoregulatory mechanisms of human responding to annual temperatures. The measurements of subjects' SCV (over 600 samples) were conducted in a naturally ventilated environment over all four seasons. The results showed a positive correlation between SCV and annual temperatures and a Boltzmann model was adopted to depict the S-shaped trend of SCV with operative temperatures from 5°C to 40°C. The SCV increased linearly with operative temperatures from 14.28°C to 20.5°C and responded sensitively for 10.19°C-24.59°C, while tended to be stable beyond that. The subjects' thermal sensations were linearly related to SCV, elaborating the relation between human physiological regulations and subjective thermal perception variations. The findings reveal the body SCV regulatory characteristics in different operative temperature intervals, thereby giving a deeper insight into human autonomic thermoregulation and benefiting for built environment designs, meantime minimizing the temperature-invoked risks to human health and well-being.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Condução Nervosa/fisiologia , Temperatura Cutânea/fisiologia , Temperatura , Adulto , China , Feminino , Corpo Humano , Humanos , Modelos Lineares , Masculino , Estações do Ano , Estudantes , Universidades , Adulto Jovem
11.
Appl Ergon ; 59(Pt A): 387-400, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27890151

RESUMO

Thermoregulation models of the human body have been widely used in thermal comfort studies. The existing models are complicated and not fully verified for application in China. This paper presents a simplified thermoregulation model which has been statistically validated by the predicted and measured mean skin temperature in warm environments, including 21 typical conditions with 400 Chinese subjects. This model comprises three parts: i) the physical model; ii) the controlled system; and iii) the controlling system, and considers three key questions formerly ignored by the existing models including: a) the evaporation efficiency of regulatory sweat; b) the proportional relation of total skin blood flow and total heat loss by regulatory sweating against body surface area; and c) discrepancies in the mean skin temperatures by gender. The developed model has been validated to be within the 95% confidence interval of the population mean skin temperature in three cases.


Assuntos
Regulação da Temperatura Corporal , Temperatura Alta , Modelos Biológicos , Temperatura Cutânea , Pele/irrigação sanguínea , Adulto , Movimentos do Ar , Superfície Corporal , China , Feminino , Humanos , Umidade , Masculino , Fluxo Sanguíneo Regional , Fatores Sexuais , Suor , Sudorese , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...